These cables are designed for aerial installation
and can withstand ice, wind & other harsh
field environment
|
|
Characteristics |
Values |
Reference
Standard |
| Span Length |
100 Mtrs |
|
Sag
During Installation
With 1 Kg per Mtr ice
load
With 75 Kms per hr wind
load
With Combined wind &
ice load |
2.0 Mtrs.
2.7 Mtrs.
3.5 Mtrs.
4.0 Mtrs. |
|
Tensile force
During installation
Permanent |
6 x W
3 x W |
IEC
60794-1-E1 |
Bending radius
Temporary, unloaded
Permanent, during installation |
15 D
20 D |
IEC
60794-1-E11 |
| Repeated bending |
30 times, with weight of 50
N |
EIA-455-104 |
| Torsion resistance |
10 cycles (± 180º ) with
load of 400 N |
IEC
60794-1-E7 |
| Crush resistance |
2000N (100 x 100 mm) |
IEC
60794-1-E3 |
| Impact resistance |
25 N-m |
IEC
60794-1-E4 |
| Kink resistance |
20 D |
IEC
60794-1-E10 |
|
Temperature range
Operation
Storage
Installation |
-30º to +70ºC
-30º to +70ºC
-10º to +50ºC |
IEC
60794-1-F1 |
| Water Penetration |
Pass |
IEC
60794-1-F5 |
|
W
= Weight in kg of 1 Km. cable
D = Diameter of cable in mm |
|
| Colour of fibres in a tube |
Blue, Orange, Green, Brown,
Slate, White,
Red, Black, Yellow, Violet, Rose & Natural
Last fibre in a tube will be Natural |
|
|
Blue, Orange, Green, Brown,
Slate, White |
| Other elements |
Natural and/Black |
|
|
Upto 12 F |
Upto 24 F |
| Cable weight (nominal) –
Kg/Km |
225 |
225 |
| Cable diameter (nominal) –
mm |
17.1 |
17.1 |
| Supplied length – Kms |
2, 4 & 6 |
2, 4 & 6 |
|
- Fibre in cable can comply to G651 / G652 Series / G655 or as desired. Properties of the cabled fibre available on request.
- The given cable cross section and characteristics will change as per specification desired by the customers.
|